How much can combined Radiant+ E3, MaxR100 and Aquene treatment save a Singapore chiller plant?
At Singapore's electricity tariff (S$0.30/kWh), grid emission factor (0.402 kg CO₂/kWh) and 300 days of 24-hour operation, a 15% saving on a 500–1,000 RT water-cooled chiller is worth S$98,000–S$197,000 a year, pays back in about 2.2 years and avoids 132–264 tonnes of CO₂ a year. Air-cooled chillers of 500–1,000 kW save S$39,000–S$78,000 a year with payback under 3 years, and a single 12–16 HP DX unit saves about S$3,500–S$4,600 a year with payback of about 2.4 years.
| Case | Solutions | Treatment cost | Saved / year at 15% | Payback at 15% | CO₂ avoided / year at 15% |
|---|---|---|---|---|---|
| 500 RT water-cooled chiller | MaxR100 + Aquene | S$216,500 | S$98,482 | 2.2 yr | 132 t |
| 1,000 RT water-cooled chiller | MaxR100 + Aquene | S$427,500 | S$196,963 | 2.2 yr | 264 t |
| 500 kW air-cooled chiller | Radiant+ E3 coil coating + MaxR100 + Aquene | S$113,000 | S$39,156 | 2.9 yr | 52 t |
| 1,000 kW air-cooled chiller | Radiant+ E3 coil coating + MaxR100 + Aquene | S$220,500 | S$78,313 | 2.8 yr | 105 t |
| 12 HP DX unit | Radiant+ E3 coil coating + MaxR100 | S$8,400 | S$3,457 | 2.4 yr | 5 t |
| 16 HP DX unit | Radiant+ E3 coil coating + MaxR100 | S$10,900 | S$4,562 | 2.4 yr | 6 t |
What assumptions are these figures based on?
Every figure on this page uses the same three Singapore inputs, so you can check any number with a calculator.
- Electricity tariff
- S$0.30 per kWh — in line with the SP Group regulated tariff for Q4 2026 (28.59 ¢/kWh before GST, 31.16 ¢/kWh with GST). Commercial contract rates vary
- Carbon emission factor
- 0.402 kg CO₂ per kWh — Singapore's average grid emission factor for 2024, published by the Energy Market Authority (EMA)
- Operating hours
- 300 days a year × 24 hours = 7,200 hours
- Money saved
- Baseline kWh × saving % × S$0.30
- CO₂ avoided
- kWh saved × 0.402 kg
- Simple payback
- Treatment cost ÷ money saved per year
- Net after 5 years
- 5 × money saved per year − treatment cost; no tariff escalation, discounting or re-treatment
These are projections for typical plants, not measured results from a single site. The saving percentages are scenarios chosen from the range measured in RCT's field projects (see the evidence below). We confirm your own baseline and saving by measuring before and after.
Why combine Radiant+ E3, MaxR100 and Aquene on one system?
Each technology removes a different loss, so their effects add up: Radiant+ E3 restores the air-cooled condenser coil, MaxR100 cleans oil fouling inside the refrigerant circuit, and Aquene improves heat transfer in the chilled-water loop.
- Radiant+ E3 coil coating — air-cooled chillers only. Restores and protects the condenser coil so heat is rejected at lower head pressure. How Radiant+ E3 works
- MaxR100 — all chillers. Releases oil films from evaporator and condenser tube walls inside the refrigerant circuit and reduces compressor friction. How MaxR100 works
- Aquene — all chillers. Graphene heat transfer fluid in the closed chilled-water loop, improving evaporator heat exchange. How Aquene works
Water-cooled chillers have no air-side coil, so they are treated with MaxR100 and Aquene only. DX and VRF units have no chilled-water loop, so they are treated with Radiant+ E3 and MaxR100.
500 RT water-cooled chiller: savings, payback and CO₂
At a 15% saving, the 500 RT water-cooled chiller saves about S$98,482 and 132 tonnes of CO₂ a year, and the S$216,500 treatment pays back in 2.2 years.
- Equipment
- Water-cooled centrifugal chiller, 500 RT (≈1,758 kW cooling)
- Solutions combined
- MaxR100 + Aquene
- Baseline consumption
- 2,188,479 kWh a year (≈304 kW average, ≈0.61 kW/RT) — S$656,544 and 880 t CO₂ a year
- Treatment cost (contract price)
- S$216,500
| Energy saving | kWh saved / year | Money saved / year | CO₂ avoided / year | Simple payback | Net after 5 years |
|---|---|---|---|---|---|
| 10% | 218,848 kWh | S$65,654 | 88.0 t | 3.3 yr | S$111,772 |
| 15% | 328,272 kWh | S$98,482 | 132.0 t | 2.2 yr | S$275,908 |
| 20% | 437,696 kWh | S$131,309 | 176.0 t | 1.6 yr | S$440,044 |
1,000 RT water-cooled chiller: savings, payback and CO₂
At a 15% saving, the 1,000 RT water-cooled chiller saves about S$196,963 and 264 tonnes of CO₂ a year, and the S$427,500 treatment pays back in 2.2 years.
- Equipment
- Water-cooled centrifugal chiller, 1,000 RT (≈3,517 kW cooling)
- Solutions combined
- MaxR100 + Aquene
- Baseline consumption
- 4,376,958 kWh a year (≈608 kW average, ≈0.61 kW/RT) — S$1,313,087 and 1,760 t CO₂ a year
- Treatment cost (contract price)
- S$427,500
| Energy saving | kWh saved / year | Money saved / year | CO₂ avoided / year | Simple payback | Net after 5 years |
|---|---|---|---|---|---|
| 10% | 437,696 kWh | S$131,309 | 176.0 t | 3.3 yr | S$229,044 |
| 15% | 656,544 kWh | S$196,963 | 263.9 t | 2.2 yr | S$557,316 |
| 20% | 875,392 kWh | S$262,617 | 351.9 t | 1.6 yr | S$885,587 |
500 kW air-cooled chiller: savings, payback and CO₂
At a 15% saving, the 500 kW air-cooled chiller saves about S$39,156 and 52 tonnes of CO₂ a year, and the S$113,000 treatment pays back in 2.9 years.
- Equipment
- Air-cooled chiller, 500 kW (≈142 RT)
- Solutions combined
- Radiant+ E3 coil coating + MaxR100 + Aquene
- Baseline consumption
- 870,139 kWh a year (≈121 kW average, ≈0.85 kW/RT) — S$261,042 and 350 t CO₂ a year
- Treatment cost (contract price)
- S$113,000
| Energy saving | kWh saved / year | Money saved / year | CO₂ avoided / year | Simple payback | Net after 5 years |
|---|---|---|---|---|---|
| 5% | 43,507 kWh | S$13,052 | 17.5 t | 8.7 yr | S$-47,740 |
| 10% | 87,014 kWh | S$26,104 | 35.0 t | 4.3 yr | S$17,521 |
| 15% | 130,521 kWh | S$39,156 | 52.5 t | 2.9 yr | S$82,781 |
| 20% | 174,028 kWh | S$52,208 | 70.0 t | 2.2 yr | S$148,042 |
1,000 kW air-cooled chiller: savings, payback and CO₂
At a 15% saving, the 1,000 kW air-cooled chiller saves about S$78,313 and 105 tonnes of CO₂ a year, and the S$220,500 treatment pays back in 2.8 years.
- Equipment
- Air-cooled chiller, 1,000 kW (≈284 RT)
- Solutions combined
- Radiant+ E3 coil coating + MaxR100 + Aquene
- Baseline consumption
- 1,740,279 kWh a year (≈242 kW average, ≈0.85 kW/RT) — S$522,084 and 700 t CO₂ a year
- Treatment cost (contract price)
- S$220,500
| Energy saving | kWh saved / year | Money saved / year | CO₂ avoided / year | Simple payback | Net after 5 years |
|---|---|---|---|---|---|
| 5% | 87,014 kWh | S$26,104 | 35.0 t | 8.4 yr | S$-89,979 |
| 10% | 174,028 kWh | S$52,208 | 70.0 t | 4.2 yr | S$40,542 |
| 15% | 261,042 kWh | S$78,313 | 104.9 t | 2.8 yr | S$171,063 |
| 20% | 348,056 kWh | S$104,417 | 139.9 t | 2.1 yr | S$301,584 |
12 HP DX unit: savings, payback and CO₂
At a 15% saving, the 12 HP DX unit saves about S$3,457 and 5 tonnes of CO₂ a year, and the S$8,400 treatment pays back in 2.4 years.
- Equipment
- DX / VRF outdoor unit, 12 HP (≈9.7 RT)
- Solutions combined
- Radiant+ E3 coil coating + MaxR100
- Baseline consumption
- 76,824 kWh a year (≈11 kW average, ≈1.10 kW/RT) — S$23,047 and 31 t CO₂ a year
- Treatment cost (contract price)
- S$8,400
| Energy saving | kWh saved / year | Money saved / year | CO₂ avoided / year | Simple payback | Net after 5 years |
|---|---|---|---|---|---|
| 10% | 7,682 kWh | S$2,305 | 3.1 t | 3.6 yr | S$3,124 |
| 15% | 11,524 kWh | S$3,457 | 4.6 t | 2.4 yr | S$8,885 |
| 20% | 15,365 kWh | S$4,609 | 6.2 t | 1.8 yr | S$14,647 |
DX baseline: rated electrical input of 1.1 kW per refrigeration ton (≈COP 3.2) running 7,200 hours a year, i.e. 9.7 RT × 1.1 kW × 7,200 h. This replaces the 270,078 kWh a year in the earlier study slide, which was about 3.5 times what a single 12 HP unit can draw.
16 HP DX unit: savings, payback and CO₂
At a 15% saving, the 16 HP DX unit saves about S$4,562 and 6 tonnes of CO₂ a year, and the S$10,900 treatment pays back in 2.4 years.
- Equipment
- DX / VRF outdoor unit, 16 HP (≈12.8 RT)
- Solutions combined
- Radiant+ E3 coil coating + MaxR100
- Baseline consumption
- 101,376 kWh a year (≈14 kW average, ≈1.10 kW/RT) — S$30,413 and 41 t CO₂ a year
- Treatment cost (contract price)
- S$10,900
| Energy saving | kWh saved / year | Money saved / year | CO₂ avoided / year | Simple payback | Net after 5 years |
|---|---|---|---|---|---|
| 5% | 5,069 kWh | S$1,521 | 2.0 t | 7.2 yr | S$-3,297 |
| 10% | 10,138 kWh | S$3,041 | 4.1 t | 3.6 yr | S$4,306 |
| 15% | 15,206 kWh | S$4,562 | 6.1 t | 2.4 yr | S$11,910 |
| 20% | 20,275 kWh | S$6,083 | 8.2 t | 1.8 yr | S$19,513 |
DX baseline: 12.8 RT × 1.1 kW/RT × 7,200 h. This replaces the 350,086 kWh a year in the earlier study slide. Units running below full load use less, so savings and payback scale with actual metered consumption.
What measured results support these saving scenarios?
The 10–20% scenarios sit inside the savings measured for each technology on real equipment.
- MaxR100 lowered a 1,100-ton centrifugal chiller's kW/TR by 14.1% (COP 4.72 → 5.50). Read the case
- Aquene recorded 15.0% to 31.3% savings across 13 chilled-water projects, including a shopping mall in Singapore at 15.0%. See the project list
- Radiant+ E3 cut energy by 12% to 28% on field projects and restored a corroded coil to new-unit efficiency in a CSIRO test. See the results
Frequently asked questions
Are these measured results?
No. They are projections for typical chillers, using measured saving ranges from RCT's field projects and Singapore's tariff, grid emission factor and operating hours. On a real project RCT measures the baseline and the saving before and after treatment.
What if my tariff or operating hours are different?
Money saved scales directly with both. For example, a plant running 12 hours a day, 300 days a year, saves half the amounts shown, and payback doubles. Ask us to rerun the numbers with your bills.
Why is the air-cooled payback longer at the same saving percentage?
An air-cooled chiller of 500–1,000 kW uses less electricity in total than a 500–1,000 RT water-cooled chiller, so the same percentage is fewer kWh, while the treatment also includes coil coating.
Which Singapore emission factor is used?
0.402 kg CO₂ per kWh, the average grid emission factor for 2024 published by the Energy Market Authority.