Project case studies

Energy saving case studies: measured results from real HVAC projects

Before-and-after results from laboratories, supermarkets, restaurants, factories, hotels, hospitals and metro stations — each with the equipment, the measurement method, the period and the numbers.

Radiant+ E3 coil coating: what has it saved?

Radiant+ E3 restores and protects condenser and evaporator coils. Measured results range from 12% to 28% lower energy in the field, and full recovery of corrosion losses in an independent CSIRO laboratory test.

  1. +12.5%EER vs corroded coil

    CSIRO laboratory test, Newcastle NSW, Australia

    Daikin split system, corroded then coated, tested to AS/NZS 3823 in a NATA-accredited lab.

    Laboratory · 2021

    Read the case study
  2. 18.5%energy

    Supermarket rooftop units, Dubai, UAE

    Seven rooftop package units; 22,113 kWh saved in 147 days, IPMVP-based dMRV.

    Retail · 2024

    Read the case study
  3. 22.5%energy per day

    Split air conditioner, Petaling Jaya, Malaysia

    Daikin DX split unit in a container cabin office; 9.14 → 7.09 kWh a day.

    Office · 2026

    Read the case study

See all Radiant+ E3 project results

MaxR100 refrigerant performance enhancer: what has it saved?

MaxR100 removes oil fouling from the inside of refrigerant circuits. Projects from 2008 to 2024 recorded 9% to 35% savings across rooftop units, refrigeration and a 1,100-ton chiller.

  1. +26–28%cooling capacity

    Restaurant rooftop units, Jacksonville, Florida, USA

    Five Carrier package units, 62.5 tons; enthalpy method, independent test firm.

    Restaurant · 2009

    Read the case study
  2. 21–24%cooling energy cost

    Two retail stores, Midwest USA

    HVAC and refrigeration, 30.75 tons; ≈80,600 kWh a year saved; payback about 6 months.

    Retail · 2011

    Read the case study
  3. 14.1%kW per TR

    1,100-ton centrifugal chiller, Yangzhou, China

    Trane CVHG chiller, R123; COP 4.72 → 5.50.

    Manufacturing · 2022

    Read the case study

See all nine MaxR100 projects

Aquene heat transfer fluid: what has it saved?

Aquene replaces the water in closed chilled-water loops with a graphene-enhanced heat transfer fluid. Thirteen completed and ongoing projects in six countries record 15% to 31% chiller-plant savings.

See the Aquene project list and awards

AI chiller system: what has it saved?

The AI chiller system adds learning, predictive control to an existing BA system. Audited savings at three metro stations were 40–50%.

  1. 40–50%HVAC electricity

    Xi'an Metro stations, Lines 4, 8 and 14, China

    Chilled-water plants and AHUs under AI control; third-party audit, October 2025.

    Transport · 2025

    Read the case study

See all AI chiller system results

What do the technologies save together in Singapore?

Combining Radiant+ E3, MaxR100 and Aquene on one system adds up their savings. At Singapore's tariff and grid emission factor, a 15% saving on a 1,000 RT water-cooled chiller is worth about S$197,000 and 264 tonnes of CO₂ a year, with payback of about 2.2 years.

  1. ≈2.2 yrpayback at 15%

    Combined treatment of water-cooled and air-cooled chillers, Singapore

    Six study cases, 12 HP DX units to 1,000 RT chillers; S$0.30/kWh, 0.402 kg CO₂/kWh, 7,200 h a year.

    Projection · Singapore basis

    Read the case study

How does RCT measure savings?

Every result on these pages comes from metered or instrument-measured data taken before and after treatment, on the same equipment, with the method and period stated.

Where a report did not include a figure — kWh, dollars or payback — we say so rather than estimate it silently. Where we calculate a figure ourselves, we mark it as RCT's calculation. Site names are withheld where the owner asked for confidentiality.