HVAC energy questions · Reducing energy use

Which HVAC energy-saving measures cause the least disruption to tenants and building operations?

Controls optimisation, refrigerant-circuit treatment and heat-transfer-fluid upgrades can be done while the system keeps running. Coil cleaning and coating need each unit shut down for a few hours, so they are scheduled unit by unit, after hours or at weekends. Chiller replacement is the most disruptive option.

Which measures need a shutdown and which do not?

Most heat-transfer and control measures need no shutdown or only a short, planned one per unit.

MeasureDisruptionNotes
AI chiller and HVAC optimisationNone — system keeps runningWireless sensors; works alongside the existing BMS, with a switch back to the original control mode
MaxR100None — added while the system runsIntroduced into the refrigerant/oil circuit during normal operation; no flushing or disassembly
AqueneMinimal — can be done during live operationFor closed chilled-water loops; no equipment replacement
Energy metering and data loggingNoneClamp-on or panel meters; needed for any verified saving
Radiant+ E3 coil restoration and coatingShort shutdown of each unit treatedSafety shutdown while coils are washed and coated; about 4–6 coils of up to 3 m² can be coated on both sides in an 8-hour day
Window filmLow — room by roomUsually installed after office hours
Chiller tube cleaning, VSD installationPlanned outage of one chiller at a timeUse standby capacity
Chiller replacementHighest — weeks of works, crane lifts, BCA submissionsUsually needs temporary cooling or a planned shutdown window

How should the work be scheduled?

Treat one unit at a time while the others carry the load, and schedule shutdown work outside tenants' operating hours.

  • Use standby (N+1) capacity: take one chiller, AHU or condensing unit off line while the rest run
  • Plan coil work for nights, weekends or public holidays in offices; quiet periods in retail and hotels; maintenance windows in hospitals and data centres
  • Start the baseline measurement two to four weeks before the work, so the shutdown does not delay the savings evidence
  • Tell tenants in advance which areas are affected and for how long
  • Combine shutdown work with scheduled maintenance to avoid a second outage

Related: measures that avoid replacing the whole system.

Ask RCT to review your plant data All HVAC energy questions

Frequently asked questions

Will tenants notice any change in comfort?

They should not. Energy-saving measures are set up to hold the agreed temperature and humidity; in RCT's Xi'an Metro case, audited indoor temperatures were steadier after AI control.

Can coil coating be done on a running system?

No. Each unit is shut down for safety while its coils are washed, prepared and coated, then returned to service the same day in most cases.

Find out how much energy your building is losing

Tell us about your chiller plant, AHUs, refrigeration or fleet. We will suggest what to measure first, and whether a grant could fund the work.