HVAC energy questions · Reducing energy use

How can I reduce chiller and air-conditioning energy use in an existing building without replacing the whole system?

Combine operational fixes with heat-transfer restoration: optimise chiller-plant controls, restore coils, remove oil fouling from the refrigerant circuit, upgrade the chilled-water fluid, and cut solar heat gain. Measured savings for individual measures range from about 10% to over 40% of the treated system's energy, depending on its starting condition — usually with payback of one to three years.

Which measures suit which type of system?

The right measures depend on whether the building has a water-cooled chiller plant, air-cooled chillers, or DX/VRF units.

SystemMeasures that do not need replacementRCT technology
Water-cooled chiller plantAI or rules-based plant optimisation; oil-fouling removal in the refrigerant circuit; graphene heat-transfer fluid in the closed chilled-water loop; tube cleaning; chilled-water reset and pump speed controlAI chiller system, MaxR100, Aquene
Air-cooled chillersCondenser coil restoration and coating, plus the measures aboveRadiant+ E3, MaxR100, Aquene
AHUs and FCUsCooling-coil cleaning and coating, fan speed control, schedule and ventilation tuningRadiant+ E3, AI optimisation
DX split and VRF unitsCondenser and evaporator coil restoration and coating; oil-fouling removalRadiant+ E3, MaxR100
Building envelopeWindow film and reflective roof or wall coatings to cut solar heat gainUV window film, passive cooling coatings

How much can each measure save?

Ranges below are measured savings on the treated equipment from RCT's projects and partners' published results; your result depends on the system's condition and operating hours.

MeasureTypical measured savingsEvidence
Radiant+ E3 coil restoration and coating10–25%Dubai rooftop units, 18.5%; Malaysia split unit, 22.5%
MaxR100 refrigerant performance enhancer16–35% typical1,100-ton chiller, kW/RT −14.1%; nine projects
Aquene heat-transfer fluid15–30% at system level13 chilled-water projects
AI chiller and HVAC optimisation30–50% in published casesXi’an Metro, 40–50% audited

Savings from several measures on the same system do not simply add up, because each one reduces the energy the next one acts on. A combined 15% on a 1,000 RT water-cooled plant is worth about S$197,000 a year at Singapore tariffs — see the Singapore savings and payback study.

In what order should I do them?

Measure the baseline, fix controls and operation, restore heat transfer, then verify — and only then consider replacing equipment that still underperforms.

  1. Measure plant kW/RT, ΔT and run hours for at least a week
  2. Correct schedules, set-points and staging (fast, low cost)
  3. Restore heat transfer: coils, refrigerant circuit, chilled-water fluid
  4. Reduce load: solar gain, ventilation, airflow
  5. Verify savings against the baseline, then decide on any replacement

RCT's energy efficiency consulting and project planning services follow this sequence.

Ask RCT to review your plant data All HVAC energy questions

Frequently asked questions

Do these measures void equipment warranties?

Check with the equipment manufacturer and your maintenance contractor before any work on equipment still under warranty, and ask the supplier for written compatibility information.

Can the work count towards BCA's Mandatory Energy Improvement target?

The regime is outcome-based, so any measure that reduces the building's measured energy use intensity counts; the qualified professional appointed for the audit decides what goes into the improvement plan.

Find out how much energy your building is losing

Tell us about your chiller plant, AHUs, refrigeration or fleet. We will suggest what to measure first, and whether a grant could fund the work.

WhatsApp us