How do refrigerant performance enhancers work?
Compressor oil circulates with the refrigerant and coats the inside of evaporator and condenser tubes. That oil film insulates the metal, so the compressor must work harder. An enhancer conditions the metal so oil releases and returns to the compressor.
MaxR100 bonds to internal metal surfaces, lifts oil fouling and stops it re-adhering, and lowers friction in the compressor. The effect shows as lower discharge pressure and temperature, lower amperage and shorter run times. It is added to the sealed circuit while the system runs, as a one-time treatment.
Are they safe for compressors?
A product is only as safe as its compatibility with your system's refrigerant, oil and materials — ask for that in writing before treatment.
- Refrigerant and oil type: confirm compatibility with your refrigerant (for example R410A, R32, R134a, R123) and oil (mineral, alkylbenzene, POE or PVE)
- Dose: follow the supplier's dosing per ton or per oil volume; over-dosing any additive is poor practice
- Sealed-system work: should be done by a licensed technician using proper charging equipment
- Oil analysis: for large chillers, an oil sample before and some weeks after treatment shows any change in oil condition
- Sight glasses, filters and driers: check them during the first service after treatment
RCT's MaxR100 is a retrofit treatment that the supplier states is compatible with common refrigerants and does not alter system tolerances. Ask RCT for the compatibility data for your specific refrigerant and oil.
Will it affect my equipment warranty?
It can. Many manufacturers' warranties exclude damage from additives they have not approved, so check before treating equipment still under warranty.
- Read the warranty terms on 'additives' or 'non-approved fluids'
- Ask the supplier for a letter on compatibility and liability
- Tell your maintenance contractor — their service contract may have similar clauses
- For out-of-warranty equipment, the question is evidence and risk, not warranty
What evidence should I ask for?
Measured before-and-after performance on equipment like yours — kWh, kW/RT or COP, or cooling capacity — by an independent party or under an agreed method.
| MaxR100 evidence | Result |
|---|---|
| 1,100-ton centrifugal chiller, China | kW/TR down 14.1%; COP 4.72 → 5.50 |
| Five rooftop units, USA (independent test firm) | Cooling capacity up 22–32% per unit |
| HVAC and refrigeration in two stores, USA | 21–24% lower cooling energy cost; payback about 6 months |
| Nine projects, 2008–2024 | 9–35% |
Frequently asked questions
Do enhancers need to be topped up?
MaxR100 is designed as a one-time treatment. If refrigerant and oil are later recovered and replaced, ask whether retreatment is needed.
Can an enhancer be combined with coil coating?
Yes. They act on different losses — refrigerant side and air side — so they are often used together.