HVAC energy questions · Specific technologies

Does coil cleaning, restoration or coating save energy, and on which equipment?

Yes, when the coils have lost heat-transfer performance to dirt, corrosion or water films. Restoring and coating coils on air-cooled chillers, AHUs, FCUs and DX/VRF units typically saves 10–25% of the unit's energy. Results depend on how degraded the coils were, the climate and operating hours — ask for metered before-and-after data, normalised for weather.

On which equipment does coil restoration and coating work?

Any air-to-refrigerant or air-to-water coil made of aluminium or copper — the condenser coils of air-cooled chillers and DX/VRF units, and the cooling coils in AHUs and FCUs.

EquipmentCoil treatedMain effect
Air-cooled chillersCondenser coilsLower condensing pressure and compressor power
DX split and VRF unitsOutdoor condenser coils, and indoor evaporator coils where accessibleLower compressor power; fewer hot-weather trips
AHUsChilled-water cooling coilsBetter heat exchange and airflow; coil drains condensate faster
FCUsCooling coilsSame as AHUs, at smaller scale
RefrigerationCondenser and evaporator coils of cold rooms and racksLower compressor power; fewer defrost problems

Water-cooled chillers have no air-side condenser coil; their heat-transfer losses are inside the tubes and refrigerant circuit, which MaxR100 and Aquene address.

How do cleaning, restoration and coating differ?

Cleaning removes dirt; restoration also removes corrosion and passivates the metal; coating adds a thin protective layer that keeps the coil performing for years.

The Radiant+ E3 Coating System follows all three steps: alkaline wash, de-rusting, Radiant+ Prime passivation, then a water-based coating about 10–15 microns thick. The super-hydrophobic surface sheds condensate, resists fouling and is expected to last more than five years. Cleaning alone recovers some performance, but corroded fins stay rough and refoul quickly.

What affects the result, and what savings are typical?

The more degraded the coil, the bigger the gain. Typical measured savings are 10–25%; well-maintained new coils gain least.

  • Starting condition: corroded, coastal or polluted-site coils gain most
  • Operating hours: 24-hour equipment repays faster
  • Climate: hot, humid Singapore conditions make heat rejection harder, so restored coils matter more
  • Application quality: surface preparation decides adhesion and life
EvidenceResult
CSIRO laboratory test, AustraliaCorrosion cut EER 12.1%; after coating EER rose 12.5%, 0.5% above the new unit
Seven rooftop package units, Dubai18.5% less energy, verified with IPMVP-based method; 5–28% by unit
Daikin split unit, Malaysia22.5% less energy per day
Field projects, Australia12–28%

What evidence should I ask a coating supplier for?

Ask for metered before-and-after energy data on comparable equipment, adjusted for weather, plus independent laboratory results and a clear description of the surface preparation.

  • A baseline of at least two to four weeks of metered kWh, with ambient temperature, before any work
  • Post-treatment data over a similar period, and how weather differences were adjusted for
  • Independent laboratory tests (for example, EER before and after on the same unit)
  • Coating thickness, expected life and maintenance requirements
  • References on similar equipment in a similar climate

See how to check whether savings claims are credible.

Ask RCT to review your plant data All HVAC energy questions

Frequently asked questions

Does the coating reduce airflow?

No. At about 10–15 microns it is far thinner than the fin spacing, and by smoothing corroded fins it usually improves airflow.

How often must coils be recoated?

The protective coating is expected to last more than five years; regular light cleaning keeps it performing.